EM Scanner - YIC Technologies

High speed 8GHz Real-time EMC and EMI diagnostic tool on your lab-bench

Authorized Distributor

YIC Technologies Logo
YIC EM Scanner
GW Instek

2024 Spring Sale 10% Off

IN STOCK & READY TO SHIP

Contact us today!

GW Instek

N9020A MXA Signal Analyzer

Accelerate the Development of Wireless Devices with the Speed, Performance & Applications to Adapt to Evolving Test Requirements

Keysight Technologies Logo
N9020A MXA Signal Analyzer

SM200B Spectrum Analyzer

The High Performance SM200B From Signal Hound: High Performance Speed, Accuracy, Security, and Agility Meet Very Low Cost

Signal Hound Logo

Trust Your Equipment to Our World Class Repair Lab

  • Huge Parts Inventory in Stock
  • Free Repair Evaluations
  • Fast Service Turnaround
  • World Class 67GHz Enabled Lab
  • Military PMEL Graduate Staff

Ask Us About Our Repair Warranty!

Manufacturers

Testimonials

  • ★★★★★

    "Fantastic deal. The oscilloscope is in very good condition. Packed for shipment to survive anything"
    Jeff
  • ★★★★★

    "Premium equipment. Excellent communication. Fast. Best value!"
    Avi
  • ★★★★★

    "Practically in new condition"
    Darcy
  • ★★★★★

    "There was a small issue; The people at BRL Test were 100% responsive and issue resolved. Thanks!"
    Mike
  • ★★★★★

    "Best packing ever! I would let you ship one of my children!"
    Todd
  • ★★★★★

    "Unit received in great shape. Passed Agilent calibration. Good job!!"
    Lee
  • ★★★★★

    "In every aspect these guys are great!"
    Sarah

Join our Newsletter

P7313 P7380A P7360A P7340A - Tektronix


Get Quote

Do you have a P7313 P7380A P7360A P7340A you want to sell?
We buy used equipment!
Learn More

Tektronix P7313 P7380A P7360A P7340A Overview

P7313 ? P7380A ? P7360A ? P7340A Tektronix Z-Active Probes


  • Signal fidelity
    • >12.5 GHz Bandwidth (P7313, typical)
    • >8.0 GHz Bandwidth (P7380A, typical)
    • >6.0 GHz Bandwidth (P7360A, typical)
    • >4.0 GHz Bandwidth (P7340A, typical)
  • Extended linear dynamic range
    • 1.25 Vp-p at 5x Attenuation (P7313)
    • 4 Vp-p at 25x Attenuation (P7313)
    • 2 Vp-p at 5x Attenuation (P7380A, P7360A, P7340A)
    • 5 Vp-p at 25x Attenuation (P7380A, P7360A, P7340A)
  • Low probe loading
    • DC Input resistance
      • 100 kΩ Differential
      • 50 kΩ Single ended
    • AC Loading
      • Zmin >200 Ω out to 10 GHz (P7313)
      • Zmin >290 Ω, 4 GHz to 8 GHz (P7380A, P7360A, P7340A)
  • Versatility
    • Make differential or single-ended (ground-referenced) measurements 1
    • Solder-down capability
    • Handheld probing with variable spacing and compliance
    • Fixtured probing
  • Interchangeable Tip-Clip? assemblies
    • Connect to a variety of devices
    • Economical
  • TekConnect® interface

1For details, please see application note 60W-18344-0, ?Making Single-ended Measurements with Differential Probes.?

APPLICATIONS
Examples include, but are not limited to:
  • MIPI® D-PHY/C-PHY, LPDDR2/3, PCI-Express, Serial ATA, USB

Z-Active probing architecture for high-speed probing applications

Tektronix created the Z-Active probe architecture and set the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while providing improved connectivity with low loading and low noise. The Z-Active architecture is a hybrid approach composed of a distributed attenuator topology feeding an active probe amplifier.

The Z-Active probes use a tiny passive probe tip element that is separate from the amplifier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal fidelity problems. However this architecture maintains high DC input resistance and presents a higher AC impedance than other probe architectures. It accomplishes this while providing significant length between the probe body and the probe attachment point to the DUT. This architecture provides the best of both worlds: high DC impedance like existing active probes and the stable high-frequency loading of Z0 probes.

Signal fidelity

You can be confident in the signal fidelity of your measurements because the Z-Active architecture provides:

  • High bandwidth
  • Excellent step response
  • Low loading
  • Low noise
  • High CMRR
  • Extended linear dynamic range

Low loading

Circuits designed for low power consumption can operate in unterminated modes with high impedance. Probing these buses in low power mode requires a probe with high impedance at low and medium frequencies. The Z-Active probes provide high impedance inputs that minimize the probe's loading on low power circuits.

Extended linear dynamic range

Many of today?s logic signals and serial bus signals require the capability to measure up to several volts peak to peak. These voltage levels may easily be viewed with the Z-Active architecture probes (P7380A, P7360A, and P7340A) with the extended linear dynamic range. With a 2.0 Vp-p linear dynamic input range at the 5x attenuation setting, you can accurately measure MIPI D-PHY and C-PHY, LPDDR2 and LPDDR3, and PCI-Express signals at reduced noise levels. In addition the 25x attenuation setting?s linear dynamic input voltage range can be used up to 5.0 Vp-p for accessing even larger signal swings found during transition times.

Versatile connectivity

The Z-Active probe design allows the probe to easily switch between soldered, handheld, or fixtured applications. This family of probes uses Tip-Clip? assemblies, an interchangeable probe tip system that enables engineers to configure their probe with the optimal tip for their application. These detachable assemblies make it possible to replace a tip for a fraction of the cost formerly associated with such hardware changes. Tip-Clips are available in several lengths and with variable tip spacing to provide flexibility for adapting to vias and other test points of differing sizes. With Tektronix Tip-Clip assemblies, Monday's solder-in probe can become Tuesday's handheld tool, simply by switching tips.

iso9001 Calibration

Calibration & Test Equipment Repair

The BRL Test Lab offers in-house ISO9001:2015 compliant calibration to its end users and industry professionals with precision accuracy, fast turn-around times, and a seamless customer experience.