BERT-1000 - Reach Technologies Bit Error Rate Testers





Request a Quotation
















No Substitutes

Add me to your email list for monthly specials.
(private list no 3rd party use)
Technical Specifications

Max. Data Rate
1.00Gbps

Max. Clock Rate
n/a

Pattern Depth
3 to 32 bits length

Extra Specifications
Bit Error Rate Tester


Product Description

The BERT-1000 series Bit Error Rate Testers handle a maximum synchronous serial bit rate of 1 Gbps per serial channel. The above chassis can be configured with up to 7 channels. More channels can be added using additional expansion chassis.
Application software and User Interfaces are provided to control from 1 to 16-channel configurations. User input is by touch screen.
The BERT-1000 has a High-Speed Interface. The High-Speed Interface is available in several configurations with different electrical levels and connectors.

BERT Generator specifications:

  • Internal clock Synthesizer: 100 bps up to 1 Gbps
  • External clock input
  • Display of actual transmitted data rate
  • Data encoding: RNRZ-L, NRZ-L, M, S
  • PRBS patterns of 2 23 -1, 2 15 -1, 2 11 -1, and 2 7 -1
  • 3-bit to 32-bit user patterns
  • Eight user defined preset patterns are stored
  • Single bit errors or bit slips may be inserted with a button push

BERT Checker specifications:

  • Accepts input data from 0 bps up to 1 Gbps
  • 1x10 -2 maximum BER detected
  • 1x10 -20 minimum BER detected
  • Errored seconds statistics
  • Display of actual received data rate
  • Data decoding: RNRZ-L, NRZ-L, M, S
  • PRBS patterns of 2 23 -1, 2 15 -1, 2 11 -1, and 2 7 -1
  • 3-bit to 32-bit user patterns
  • Eight user defined preset patterns are stored