6330 - Slaughter Hipots


Contact for Quote

  • Model: 6330
  • Manufactured by: Slaughter
  • Max. Output AC Voltage: 3.500kV
  • Max. Output DC Voltage: 3.500kV
  • Output AC Current: 30.0mA
  • Output DC Current: 5.0mA
  • Extra Specifications: 6-in-1 Multi-Function Electrical Safety Tester

The 6330 allows manufacturers to perform six of the most common electrical safety tests in a single instrument. This 6-in-1 Electrical Safety tester will perform AC Hipot, DC Hipot, Insulation Resistance, Ground Bond, Functional Run, and Line Leakage Tests in a single instrument. Equipped with the latest technology and features at a cost-effective price, the 6330 is a good solution for applications requiring multiple safety tests.

  • Six tests in one instrument - New 6-in-1 design allows manufacturers to cost-effectively perform multiple electrical safety tests in a single instrument. The 6330 will perform AC Hipot, DC Hipot, Insulation Resistance, Ground Bond, Functional Run, and Line Leakage Tests
  • Line Leakage test mode - The 6330 provides 5 different measuring devices built in allowing for Line Leakage testing to common agency specifications
  • Functional Run test mode - The 6330 can monitor minimum and maximum readings for Voltage, Current, Power, Power Factor, and Leakage Current
  • Multiple test memories - The 6330 provides 10 memories with 20 steps per memory. It is possible to program multiple testing procedures and store them in the instrument''s internal memory. This is beneficial for manufactures that test multiple products on one manufactured line
  • Simple menu control - All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters
  • PLC remote inputs and outputs - The standard 9-pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test, Reset, Interlock, and Memory Recall 1-6. This gives the user all the basic remotes required to configure the tester through simple PLC relay control
  • Electronic dwell settings - Electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested
  • Electronic ramping - Electronic ramping provides a gradual and time method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUTs
  • Tamper proof front panel controls - This makes it possible to limit user access to the setup screens so that only authorized personnel can change test parameters
  • No load setup of trip current and output voltage - This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage present
  • Software calibration control - The 6330 is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows the instrument to be completely calibrated without removing any covers and exposing the technician to hazardous voltages
  • Line and load regulation - This tester maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements
  • Single step test mode - In this mode, the 6330 can be configured to perform each test individually as a single step. This provides the manufacturers flexibility in configuring their testing procedure
  • Milliohm offset capability - Milliohm offset minimizes the effect of test lead or test fixture resistance in Ground Bond testing
  • Fail stop ON/OFF mode - This allows the 6330 to be configured to continue testing after detecting a failure. All pass/fail results are displayed at the complete of the test cycle
  • Flashing high voltage indicator - A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety
  • Low current sense - The low current sense feature monitors the minimum level of current flow, thus ensuring that the DUT is properly connected and that the Hipot test is being performed
  • Front panel LCD - A front panel LCD allows the operator to monitor the test. The display holds the results after a test item failure so that the operator can easily review the test results. Failure indications are clearly displayed
  • Output voltage fine adjustment - To make the 6330 usable in all types of applications, the operator can manually bring the voltage up or down in 10 volt increments by simply pressing the up and down arrow keys. This makes it very easy to adjust the output voltages even while the instrument is in the dwell mode so you can analyze test results at different voltages
  • Continuous duty cycle ratings - The 6330 does not have any requirements to be shut down during the day even when used at full output
  • Adjustable output current and milliohm trip currents