CDN-C50E - Com-Power CDN Coupling Decoupling Networks

$990.00

  • Model: CDN-C50E
  • Units in Stock: 1
  • Manufactured by: Com-Power
  • Extra Specifications: New in box.
 
<h2>Com-Power CDN-C50E</h2>Com-Power CDN-C50E is one of the series of Coupling/Decoupling Networks designed to comply for testing product for conducted immunity per IEC/EN 61000-4-6 and CISPR 16-1-2. The CDN-C50E is designed for testing products that uses 50 Ohm coaxial cables for data communication. It has 50 Ohm BNC connectors for both EUT and AE power connection. The CDNC50E can handle up to 1 Amp of current. The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF Input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding. This is a pre-packaged solution that includes an ACS series power amplifier and all accessories required for the test. Com-Power CDNs are individually calibrated. All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system.

Product Name Coupling Decoupling Network (CDN)
Compliant Test Standards IEC / EN 61000-4-6
Application 50 Ohm Coaxial Cables
Frequency Range 150 kHz to 230 MHz
RF Input Voltage 40 V (Max)
RF Input Connector 50 Ω BNC (Female)
Voltage Rating 310 V AC / 440 V DC (Line to Ground)
Current Rating 1 Amp (Max)
AE and EUT Connections 50 Ohm Female BNC
Common Mode Impedance 150 kHz - 26 MHz: 150Ω ± 20Ω
26 MHz - 80 MHz: 150Ω + 60Ω / ? 45Ω
80 MHz - 230 MHz: 150Ω + 60Ω / ? 60Ω
Voltage Division Factor 9.5 dB +3 / -1
Decoupling of Common
Mode Disturbance
≥ 40dB (EUT/AE)
Dimensions 6 x 6 x 13 inches
15.2 x 15.2 x 33 cm
Weight 5 lbs.
2.3 kg
Accessories Available from
BRL Test for setting test
levels and running the test
ADA-C50/C75 shorting adapters
ADA-515-2 150 Ω to 50 Ω adapters
TEP-050 50 Ω Terminator
ATTN-6-100W Power Attenuator
DCU-300-100W Directional Coupler
ASC series Power Amplifiers