AQ6317B - Ando Optical Spectrum Analyzers


Get Quote

  • Model: AQ6317B
  • Manufactured by: Ando
  • Form Factor: Diverse analysis functions: WDM, LD, LED, FBG, etc.
  • High end wavelength limit: 600nm to 1750nm, measures light to -90dBm.
  • Wavelength Resolution: 0.015 nm
  • Instrument Type: Benchtop

Ando AQ6317B

Optical Spectrum Analyzer

Advanced capabilities to a wide range of applications, from light source evaluation to measurement of loss wavelength characteristics in optical devices. Especially at C-band and L-band, the unit achieves high wavelength accuracy and wavelength linearity, and can evaluate optical devices for WDM. Analysis functions make operation and expandability simple.
Diverse analysis functions: WDM, LD, LED, FBG, etc.
Wavelength accuracy: ±0.05 nm wavelength accuracy in the 1550 nm band, with ±0.01 nm
wavelength linearity.
Bandwidth: 600nm to 1750nm, measures light to -90dBm.
Polarization dependency: ±0.05dB
Accuracy: ±0.3dB
Wavelength resolution: 0.015 nm
Max power measurement: +20dBm (100mW)
9.4-inch color LCD display
Trace memory: 32 traces, 20 programs
In conjunction with the AQ4321 Tunable Laser Source, the AQ6317B can achieve high wavelength resolution/wide dynamic range with high-speed synchronous sweep function, and result insertion loss, passed central wavelength and linearity as evaluation parameter of optical MUX/DEMUX
Optical fiber amplifier (EDFA) evaluation The ASE interpolation method is used to measure gain and NF, key parameters for optical fiber amplifier evaluation. In conjunction with the AQ8423Z optical amplifier analyzer, the system can accurately measure gain and NF with the pulse method, which is optimum for evaluation of WDM optical fiber amplifiers. AQ6317B Low Prices on Sales and Repairs at BRL Test.